Description
Domestic Wastewater treatment plant type ACO SBREM 40 D2.35 by means of a Sequential Biological Reactor (SBR) manufactured at glass-reinforced plastic (GRP), in horizontal format for underground installation. With treatment capacity for 40 users and a hydraulic demand of 6 m³/day, with high purification performance in compliance with RD 509/1996 and the UNE-EN 12566-3. Solution consisting of 1 compact unit of dimensions 4010mm in lenght, 2350mm in width and 2487mm in height. With inlet and outlet connection DN160. Total installed power: 2,05kW. Weight: 848kg.
Code:0PK00589
Code:0PK00589
Characteristics
Benefits
- Compact water treatment plant
- Easy installation and maintenance
- Low power consumption
- The position of the pump avoids the outflow of posible floats
Areas of application
- Equipment for the treatment of domestic wastewater by oxidation in small and medium-sized communities
Decanter
- Anaerobic degradation of the accumulated organic matter
Reactor
- Removal of organic matter and nutrients
- Includes turbine type compresor for 1-3mm bubbles
Electrical panel and PLC
- Three-phase current 400 V
- IP - 44 protection
- Installed power 2,05 kW
Effluent qualities
- BOD5 (mg/l)<15
- COD (mg/l)<61
- SS (mg/l)<15
Effluent qualities
- BOD5 (%) = 92
- COD (%) = 90
- SS (%) = 94
- The equipment is designed to treat waste water with the following composition: BOD5: 400ppm, COD: 600ppm, SS: 450ppm
Operation
- The system is carried out in the following stages:
1 - Primary settling tank: sedimentation and settling of the influent. The water is pumped to the reactor in a programmed way at the beginning of a cycle. Its operation is not affected by the hourly discontinuity of the influent flow. It decants part of the solids and also anaerobically degrades the accumulated organic matter.
2 - Biological clarifier reactor: The treatment sequences are as follows: - Filling: reception of a certain volume of water from the primary settling tank by pumping.
- Reactor: in the reaction stage, aerobic phases (presence of oxygen) are combined with anoxic phases (without oxygen) which allows the removal of organic matter and nutrients.
- Sedimentation: during this phase and in the absence of agitation and aeration, the sludge settles, leaving the sludge at the bottom and the clarified at the top.
- Emptying: the treated water is pumped out.
Technical Specifications

Dimensions 1
- Model:
- SBREM 40
- EH:
- 40
- Flow rate (m³/day):
- 6
- Weight (kg):
- 848
Dimensions 2
- L
(mm): - 4010
- A (mm):
- 2350
- H (mm):
- 2487
- H1 (mm):
- 2160
- H2 (mm):
- 2110
- H3 (mm):
- 2450
- TD (mm):
- 327
- DN:
- 160
- DN2:
- 50
Technical datasheets
Manuals and installation sections
Certificates