Description
Wastewater treatment plant type ACO ROX 20 D2 through a total oxidation system manufactured in glass-reinforced plastic (GRP), in horizontal format for underground installation. With treatment capacity for 20 users and a hydraulic demand of 3 m³/day, with high purification performance in compliance with RD 509/1996 and UNE-EN 12566-3. Solution formed by 1 compact equipment with dimensions 3290mm in length, 2000mm in width and 2150mm in height. With inlet and outlet connection DN125 and with 2 access covers to the inside of the equipment of dimensions Ø567mm made in polyethylene. Total installed power: 5,28kW. Weight: 380kg.
Code:0PK00021
Code:0PK00021
Characteristics
Easy installation and maintenance.
- Low power consumption.
- Benefits
- Compact water treatment plant.
Areas of application
- Equipment for the treatment of sewage by oxidation in small and medium-sized communities.
Roughing (Recommended)
- Manufactured in GRP.
- Filter with 10 mm pitch.
Reactor
- Removal of organic matter and nutrients.
- Air supply by compressor(s).
- Fine bubble air diffusers between 1-3 mm.
Clarifier
- Sludge recirculation by pumping.
Electrical panel and PLC
- Single-phase current 230V.
- IP-44 protection
- Installed potency 1,01kW
BOD5 (mg/l) <10
- COD (mg/l) <50
- SS (mg/l) <10
- Effluent qualities
Effluent qualities
- BOD5 (%) = 95
- COD (%) = 89
- SS (%) = 96
- The equipment is designed to treat waste water with the following composition: BOD5: 400ppm, COD: 600ppm, SS: 450ppm
Stages of operation:
- 1- Screen (recommended): Coarse solids carried by the water are intercepted by a grate at the inlet of the equipment. For small populations, due to the high variability of the influent, it is recommended to install a decanter upstream.
- 2- Biological oxidation: In the biological reactor, the biological decomposition of organic matter takes place thanks to the supply of air and the generation of aerobic microorganisms.
- 3- Decanting: The sludge resulting from the decomposition of the organic matter is calmed, deposited inside the decanter. The decanted sludge is recirculated back to the reactor by pumping .
Technical Specifications

Dimensions 1
- Model:
- ROX 20
- EH:
- 20
- Hydraulic demand (m³/day):
- 3
- Weight (kg):
- 380
- :
Dimensions 2
- TD (mm):
- 400
- DN:
- 125
- DN2:
- 20
- L (mm):
- 3290
- A (mm):
- 2000
- H (mm):
- 2150
- H1 (mm):
- 1738
- H2 (mm):
- 1688
- H3 (mm):
- 2150
Technical datasheets
Manuals and installation sections
Certificates